7.2 DESCRIPTION
7.2.1 SPECIFICATION ABOUT THE THERMAL PROTECTION
* The change of HI / LO have hysterisis curve below.
Reading value of the season and FAN drive.
This model controls the FAN drive by MAIN u-com pin 149 (FAN ON / OFF) pin 17 (Cange of FAN control voltage) ,
not by the traditional PWM.
Assign FAN : HIGH FAN : LO STOP
IC5206 149pin
H
H
L
FAN_CONT
IC5206 17pin
H
L
-
FAN_CONT_POW
Set State and FAN Drive
POWER PSW1 State Control FAN Operation
ON ON ON According to the reading value of above table sensor. ON (HIGH/LO/STOP)
ON ON DT_REC According to the reading value of above table sensor. ON (HIGH/LO/STOP)
OFF STB FAN CONT OFF
[ Outline Circuit ]
REG
FAN_vcc
Vref = 2.65V
H : On
L : Off
Vo
UCOM
17
149
H
:
Vo = 9.57V
L
:
Vo = 7.10V
T4
(Outside air 60°C)
T3
(Outside air 38.5°C)
T2
(Outside air 35.5°C)
T1
(Outside air 33°C)
FAN : STOP FAN : LO FAN : HIGH FAN : HIGH FAN : LO FAN : STOP FAN : STOP FAN : LO FAN : HIGH SD
T0
(Outside air 30°C)
Aime
(Sensor position)
Aime
(Outside air of
Unit)
AD value
(Thermister)
8 bit
AD value
(Thermister)
10 bit
76pin TEMP2 T4 setting 60°C55°C
T3 setting 46°C 38.5°C
T2 setting 41°C 38.5°C
T1 setting 40°C33°C
T0 setting
105
131
139
141
149
420
524
556
564
596 35.5°C30°C