EasyManua.ls Logo

Pioneer PDP-506PG - • Power-down diagnosis (defective points)

Pioneer PDP-506PG
99 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PDP-506PE
65
5678
56
7
8
C
D
F
A
B
E
OVP : OVER VOLTAGE PROTECT
UVP : UNDER VOLTAGE PROTECT
• Power-down diagnosis (defective points)
Number
of Blinks
PD Circuit in
Operation
Defective PCB
Assy
Reason for PD
(Power-down)
Point to be Checked Possible Defective Part Remarks
2 POWER POWER SUPPLY
3 SCAN
50 (43) SCAN A, B
VH UVP
SCAN IC SCAN IC VH-GNDH short-circuit
50 (43) Y DRIVE
Y SUS BLOCK IC2252, IC2253
VSUS-SUSOUT,
SUSOUT-SUSGND short-
circuit
VH DC/DC IC2502, L2501
Disconnection of cable detected
CN2001, CN2350
50 (43) X DRIVE VH UVP IC1202 IC1202
VSUS-SUSOUT,
SUSOUT-SUSGND short-
circuit
4 SCN-5V
50 (43) SCAN A, B
Disconnection of cable detected
CN2401, CN2402
IC5V UVP
SCAN IC SCAN IC
50 (43) Y DRIVE
IC5V DC/DC Q2605, R2647
Y SUS BLOCK R2352
6 Y-DCDC 50 (43) Y DRIVE
VOFS UVP
VOFS DC/DC Q2606, R2619, R2620
Y SUS BLOCK IC2252, IC2253, Q2280, Q2281 MSKS-SUSOUT short-circuit
Vprst UVP Vprst Regulator Q2531, Q2532, IC2535
7 Y-SUS 50 (43) Y DRIVE
Power-down caused by
detection of middle-point
voltage
Y RESONANCE BLOCK IC2101
Y SUS BLOCK Q2221
8 ADRS 50 (43) ADDRESS
Address power-down ADDRESS RESONANCE BLOCK D1634 V+ADR-GND_ADR short-circuit
Disconnection of cable detected
CN1501, CN3501-CN3504
9 XDRIVE 50 (43) X DRIVE
Disconnection of cable detected
CN1001
10 X-DCDC 50 (43) X DRIVE
Disconnection of cable detected
CN1201
VRN UVP
VRN DC/DC Q1323, R1332, R1333
X SUS BLOCK R1204, Q1272
11 X-SUS 50 (43) X DRIVE
Power-down caused by
detection of middle-point
voltage
X RESONANCE BLOCK IC1101

Related product manuals