EasyManua.ls Logo

Pitco L22-355 - Recovery Test, Diagnostic, and Range Settings

Pitco L22-355
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spin Fryer I12 Cooking Computer
Pitco P/N 60149505
L22-355 Rev 1 Page 20 of 28
5.5 Recovery Test Values
This menu is identical to Recovery Times section 4.4 except is displayed
instead of [SERVICE].
5.6 Diagnostic Menu Entry
This menu is identical to Diagnostic Menu section 4.5 except
is displayed instead of [SERVICE].
5.7 Ready Level
This menu is identical to Ready Level section 4.6 except is
displayed instead of [SERVICE].
5.8 Operating Temperature Range
This menu is identical to Temperature Operating Range section 4.7 except
is displayed instead of [SERVICE].
5.9 High Limit Value
With display showing press product key 8.
Pressing product key 8 forces the control to display the temperature above
the set temperature, where the high limit alarm will sound. This is a display
only value, this value cannot be changed with a keypad entry.
Press the key. Display now shows .
Note: Factory default value is 40°F over set temperature, or 410°F absolute,
whichever is less.
4
6
7
8
5

Table of Contents