User manual - ATR144- 17
7.2  Meaning of status lights (Led)
3 C
ON when the command output 1 is active. In 
case of motorized valve control it is ON during 
valve opening and flashes during valve closing.
4 A1 ON when alarm 1 is active.
5 A2 ON when alarm 2 is active.
6 T
ON when the controller is executing an 
auto-tuning cycle.
7 M ON when “Manual” function is active.
8 R
ON when the controller communicates through 
serial. Flashes when the remote setpoint is 
enabled.
7.3  Keys
9
•  Increases the main setpoint.
•  During configuration allows to scroll the 
parameters or the groups of parameters.
•  Increases the setpoints.
10
•  Decreases the main setpoint.
•  During configuration allows to scroll the 
parameters or the groups of parameters.
•  Decreases the setpoints.
11
SET
•  Allows to visualize command and alarm 
setpoints.
•  During configuration allows to enter the 
parameter to be modified and confirms the 
variation.
12
FNC
•  Allows to enter the Tuning launch function, 
automatic/manual selection.
•  During configuration works as exit key 
(ESCAPE).