RS232 Codes
Planar RPS and Video Controller RS232 User Guide Page | 36
020-1332-00I
ZONE.ORDER Zone Stack Order 2615 =? Integer String ZONE.ORDER(5)?
ZONE.ORDER(5):-4
Gets / sets the order position of the
specified zone in the zone stack. Smaller
numbers are toward the back. Only
applicable to the active display/preset.
No 4.0 Yes No
ZONE.RECT Zone Display
Area
2606 =? Integer String ZONE.RECT(5)?
ZONE.RECT(5):1920 1080 1920 1080
Gets / sets for specified zone in configured
wall in order: x offset pixel from zero x
position in wall, y offset pixel from zero y
position in wall, zone x area pixel size, zone
y area pixel size. Only applicable to the
active display/preset.
No 4.0 Ye s No
ZONE.RESTORE Restore Zone 2607 ! Integer ZONE.RESTORE(5)
ZONE.RESTORE(5):@ACK
Undo of the last zone modification
performed on the specified zone. Zone
specified must have had the last action
performed. Only applicable to the active
display/preset.
No 4.0 Yes No
ZONE.SOURCE Zone Input 2608 =? Integer String ZONE.SOURCE(1)?
ZONE.SOURCE(1):"HDMI VC2.IN2"
Gets / sets the input routed to a zone. Only
applicable to the active display/preset.
No 4.0 Ye s No
Command Description
Numeric Command Code
Operators
Modifiers Operands Example Notes
Standalone Component Command
Firmware Version Active
Functional in Fast Start Standby
Functional in Low Power Standby