'#! HE)QQ7!?O73/A!')!B<5RO<5)!<2R!;263<EE<37. 2 ! S07R)! !
XA<2T)!X.22)/37.26!
You start changing connections with Plexxi Switch 2e 3 W3, then Plexxi Switch 2e 4, next Plexxi Switch
2e 5, and finally number 6. The following table lists the recabling required by direction and by QSFP
port number.
Switch 3 W3 to Switch 6 E3
1. Unplug Switch 1 E3 (Q6)
2. Plug the freed end into Switch 6 E3 (Q6)
Switch 4 W2 to Switch 6 E2
1. Unplug Switch 1 E2 (Q4)
2. Plug freed end into Switch 6 E2 (Q2)
Switch 4 W3 to Switch 1 E3
1. Unplug Switch 2 E3 (Q6)
2. Plug freed end into Switch 1 E3 (Q6)
Switch 5 W1 to Switch 6 E1
1. Unplug Switch 1 E1 (Q2)
2. Plug freed end into Switch 6 E1 (Q2)
Switch 5 W2 to Switch 1 E2
1. Unplug Switch 2 E2 (Q4)
2. Plug freed end into Switch 1 E2 (Q4)
Switch 5 W3 to Switch 2 E3
1. Unplug Switch 3 E3 (Q6)
2. Plug freed end into Switch 2 E3 (Q6)
Switch 6 W1 to Switch 1 E1
1. Plug Switch 6 W1 (Q1) to Switch 1 E1 (Q2)
Switch 6 W2 to Switch 2 E2
1. Plug Switch 6 W2 (Q3) to Switch 2 E2 (Q4)
Switch 6 W3 to Switch 3 E3
1. Plug Switch 6 W3 (Q5) to Switch 3 W3 (Q6)