EasyManua.ls Logo

+GF+ Signet 4630 - Ordering Information

+GF+ Signet 4630
48 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Georg Fischer Signet LLC, 3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057
For Worldwide Sales and Service, visit our website: www.gfsignet.com • Or call (in the U.S.): (800) 854-4090
For the most up-to-date information, please refer to our website at www.gfsignet.com
3-4630.090 Rev M 04/15 English © Georg Fischer Signet LLC 2015
463X Chlorine Analyzer
Mfr. Part No. Code Description
3-4630-10 159 001 748 Chlorine panel, transmitter, free chlorine sensor (0 to 2 ppm), w/ sensor electronics, no pH sensor
3-4630-11 159 001 749 Chlorine panel, transmitter, free chlorine sensor (0 to 2 ppm) w/ sensor electronics, pH sensor w/ electronics
3-4630-20 159 001 691 Chlorine panel, transmitter, free chlorine sensor (0 to 5 ppm) w/ sensor electronics, no pH sensor
3-4630-21 159 001 692 Chlorine panel, transmitter, free chlorine sensor (0 to 5 ppm) w/ sensor electronics, pH sensor w/ electronics
3-4630-30 159 001 750 Chlorine panel, transmitter, free chlorine sensor (0 to 20 ppm), w/ sensor electronics, no pH sensor
3-4630-31 159 001 751 Chlorine panel, transmitter, free chlorine sensor (0 to 20 ppm) w/ sensor electronics, pH sensor w/ electronics
3-4632-10 159 001 768 Chlorine panel, transmitter, chlorine dioxide sensor (0 to 2 ppm), with sensor electronics, no pH sensor
3-4632-11 159 001 769
Chlorine panel, transmitter, chlorine dioxide sensor (0 to 2 ppm), with sensor electronics, pH sensor w/ electronics
3-8630-3P 159 001 673 Panel mount chlorine and pH transmitter
3-2630-1 159 001 746 Free Chlorine electrode, 0 to 2 ppm (mg/L)
3-2630-2 159 001 662 Free Chlorine electrode, 0 to 5 ppm (mg/L)
3-2630-3 159 001 747 Free Chlorine electrode, 0 to 20 ppm (mg/L)
3-2632-1 159 001 767 Chlorine Dioxide electrode, 0 to 2 ppm (mg/L)
3-2724-00 159 001 545 Electrode, pH, at, PT1000, ¾ in. NPT
3-2750-7 159 001 671 pH - Inline Electronics, Digital (S
3
L), 4.6 m (15 ft) cable
3-2650-7 159 001 670 Chlorine - Inline Amperometric Electronics, Digital (S
3
L), 4.6 m (15 ft) cable
Accessories and Replacement Parts
3-4630.390 159 001 688 Rebuild kit, O-rings, boots, screws, 1 lter screen
3-4630.391 159 001 689 Pressure regulator with 1 spare lter screen
3-4630.392 159 001 690 Acrylic ow cell complete with all components and connections
3-4630.393 159 310 162 Flow Switch Kit, PP
7300-0024 159 001 693 24 VDC Power Supply
3-2630.391 159 001 674 Free Chlorine electrolyte, 30 mL (2)
3-2632.391 159 310 160 Chlorine Dioxide electrolyte, 30 mL (2)
3-2630.392 159 001 675 Free Chlorine replacement PVDF membrane (1) (sensors sold prior to Nov 1, 2012)
3-2630.394 159 310 164
Free Chlorine and Chlorine Dioxide Replacement PTFE membrane (1) (sensors sold after Nov 1, 2012)
3-2630.396 159 001 676
Free Chlorine sensor replacement kit - (2) electrolyte, (2) PVDF membranes, and Polishing Paper
(sensors sold prior to Nov 1, 2012)
3-2630.398 159 310 166
Free Chlorine Sensor maintenance kit - (2) electrolyte, (2) PTFE membranes, (2) Silicone Bands, and Polishing
Paper (sensors sold after Nov 1, 2012)
3-2632.398 159 310 165 Chlorine Dioxide maintenance kit - (2) electrolyte, (2) PTFE membranes, (2) Silicone Bands, and Polishing Paper
1220-0021 159 801 182 O-ring FPM
3-0700.390 198 864 403 pH Buffer Kit (1 each 4, 7, 10 pH buffer in powder form, makes 50 mL of each)
3822-7004 159 001 581 pH 4.01 buffer solution, 1 pint (473 mL) bottle
3822-7007 159 001 582 pH 7.00 buffer solution, 1 pint (473 mL) bottle
3822-7010 159 001 583 pH 10.00 buffer solution, 1 pint (473 mL) bottle
3-2700.395 159 001 605 Calibration kit: included 3 polypropylene cups, box used as cup stand, 1 pint pH 4.01, 1 pint pH 7.00
3-2759 159 000 762 pH/ORP System Tester (adapter cable sold separately)
3-2759.391 159 000 764 2759 DryLoc Adapter Cable (for use with 2750 and 2760)
Ordering Information