For optimum performance it is recommended to have a battery pack which under load
measures greater than 4.5 Vat ambient room temperature. Mandatory battery replacement is
required if any of the following conditions exist and is to be performed by one of Pointer
Avionics certified maintenance shops listed at WWW.SKYHUNTER406.COM.
If Battery has reached expiration date. (5 years)
If cumulated transmitter "ON" time is more than 1 hour since last battery replacement,
indicated by 3 red flashes on the Remote Switch or 3 amber flashes on the ELT LED,
during the ARM SelfTest.
If the ELT has been on for an undetermined amount oftime.
If the ELT has been activated during an emergency.
Fig. 9 - Battery Cover Removal