EasyManua.ls Logo

Polycom 1725-11530-310 - Page 207

Polycom 1725-11530-310
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration Files
A - 53
Server <server/>
RTCP-XR <rtcpxr/>
Central Report Collector <collector/>
This configuration attribute is defined as follows:
Attribute
Permitted
Values
Default Interpretation
voice.qualityMonitoring.collector.enable.
periodic
0, 1 0 Enables generation of periodic
quality reports throughout a call.
voice.qualityMonitoring.collector.enable.
session
0, 1 0 Enables generation of a quality
report at the end of each call.
voice.qualityMonitoring.collector.enable.
triggeredPeriodic
0, 1, 2 0 Controls the generation of periodic
quality reports triggered by alert
states.
If set to 0, alert states do not cause
periodic reports to be generated.
If set to 1, periodic reports will be
generated when an alert state is
critical.
If set to 2, periodic reports will be
generated when an alert state is
either warning or critical.
Note: This parameter is ignored
when
qualityMonitoring.collector.e
nable.periodic
is set 1, since
periodic reports are sent throughout
the duration of a call.
voice.qualityMonitoring.collector.period 5 to 20 20 The time interval between
successive periodic quality reports.

Table of Contents

Related product manuals