EasyManua.ls Logo

Polycom 1725-11530-310 - Page 208

Polycom 1725-11530-310
373 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Administrator’s Guide SoundPoint IP / SoundStation IP
A - 54
Alert Reports <alert/>
This configuration attribute is defined as follows:
Attribute
Permitted
Values Default Interpretation
voice.qualityMonitoring.collector.
alert.moslq.threshold.warning
Null, 15 to 40 Null Threshold value of listening MOS
score (MOS-LQ) that causes phone
to send a warning alert quality
report. Configure the desired MOS
value multiplied by 10. If set to Null,
warning alerts are not generated
due to MOS-LQ.
For example, a configured value of
35 corresponds to the MOS score
3.5.
voice.qualityMonitoring.collector.
alert.moslq.threshold.critical
Null, 15 to 40 Null Threshold value of listening MOS
score (MOS-LQ) that causes phone
to send a critical alert quality report.
Configure the desired MOS value
multiplied by 10. If set to Null,
critical alerts are not generated due
to MOS-LQ.
For example, a configured value of
28 corresponds to the MOS score
2.8.
voice.qualityMonitoring.collector.alert.
delay.threshold.warning
Null, 10 to
2000
Null Threshold value of one way delay
(in ms) that causes phone to send a
critical alert quality report. If set to
Null, warning alerts are not
generated due to one way delay.
One-way delay includes both
network delay and end system
delay.
voice.qualityMonitoring.collector.alert.
delay.threshold.critical
Null, 10 to
2000
Null Threshold value of one way delay
(in ms) that causes phone to send a
critical alert quality report. If set to
Null, critical alerts are not generated
due to one way delay. One-way
delay includes both network delay
and end system delay.

Table of Contents