4 - 2
Power and Startup
Symptom Problem Corrective Action
There are power issues. The Polycom CX700 IP phone
has no power.
Do one of the following steps:
Verify that no lights appear on the unit
when it is powered up.
If using PoE, verify that PoE is present
on that port. Ask your system
administrator to check the appropriate
LED or readout or port at the hub.
If using PoE, verify that the network
cable is plugged into the correct port
on the Polycom CX700 IP phone.
If using AC power, check if the phone
is properly plugged into a functional
AC outlet.
If using AC power, make sure that the
phone isn't plugged into a plug
controlled by a light switch that is off.
If plugged into a power strip, try
plugging directly into a wall outlet
instead.
If using AC power, try the phone in
another room where the electricity is
known to be working on a particular
outlet.
The Polycom CX 700 IP phone
appears to be fine, but there is
no interaction between the
handset and the Microsoft Lync
2010 client.
There may be problems with the
Microsoft Lync 2010 Server
software.
Contact your system administrator to
ensure your account is configured
properly and that the Microsoft Lync 2010
Server software is properly installed and
configured.

Table of Contents

Other manuals for Polycom CX700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom CX700 and is the answer not in the manual?

Polycom CX700 Specifications

Power IconPower
power over EthernetIEEE 802.3af Class 2
maximum power consumption13 Watts
LCD Display IconLCD Display
display size5.7 inches
display typeamorphous-TFT Active-Matrix Transmissive
display resolution320x240
Audio IconAudio
frequency response30 – 20kHz
signal-to-noise ratio78 dB (@ 1kHz)
dynamic range>80 dB (@ 1kHz)
total harmonic distortion + noise<0.08% (@ 1 kHz)
Operating Environment IconOperating Environment
operating temperature range-10°C to 40°C
relative humidity80% max (non-condensing)
operating altitude range-304.8 meter to 3962.4 meter
Weight and Dimensions IconWeight and Dimensions
dimensions when not tilted252.7 x 268.6 x 91.3 mm
dimensions when tilted up193.2 x 268.6 x 192.1 mm
unit weight2.1 kg
handset weight200 g
shipping weight2 kgs