9
Poolex Jetline Premium Inverter
Test conditions
90 120 150 200
Air
(1)
26°C
Water
(2)
26°C
INVERTER MODE
Heating power (kW) 12.2~2.78 15.1~3.47 20.3~4.67 28.0~6.45
Consumption (kW) 1.79~0.209 2.22~0.261 3.01~0.354 4.11~0.485
COP (Coeff. of performance) 13.3~6.8 13.3~6.8 13.2~6.75 13.3~6.8
Air
(1)
26°C
Water
(2)
26°C
SILENCE MODE
Heating power (kW) 8.8~2.78 10.6~3.47 14.21~4.67 19.6~6.45
Consumption (kW) 1.11~0.209 1.34~0.261 1.81~0.354 2.48~0.485
COP (Coeff. of performance) 13.3~7.9 13.3~7.9 13.2~7.85 13.3~7.9
Air
(1)
15°C
Water
(2)
26°C
INVERTER MODE
Heating power (kW) 9.03~2.09 12.1~2.77 15.1~3.45 20.1~4.62
Consumption (kW) 1.86~0.286 2.49~0.379 3.13~0.479 4.16~0.633
COP (Coeff. of performance) 7.3~4.83 7.3~4.85 7.2~4.83 7.3~4.83
Air
(1)
15°C
Water
(2)
26°C
SILENCE MODE
Heating power (kW) 6.37~2.09 8.4~2.77 10.56~3.45 14.08~4.62
Consumption (kW) 1.15~0.286 1.53~0.379 1.92~0.479 2.56~0.633
COP (Coeff. of performance) 7.3~5.5 7.3~5.5 7.2~5.5 7.3~5.5
Air
(1)
15°C
Water
(2)
26°C
FIX MODE
Heating power (kW) 6,01 8,01 9,5 13,01
Consumption (kW) 1,06 1,425 1,69 2,31
COP (Coeff. of performance) 5,62 5,62 5,61 5,62
Air
(1)
35°C
Water
(2)
27°C
Cooling capacity (kW) 4.8~2.7 6.5~4.01 7.9~4.9 10.5~6.9
Consumption (kW) 1.41~0.586 1.91~0.87 2.32~1.07 3.09~1.5
Avg. EER (Energy Efciency Ratio) 4.6~3.4 4.6~3.4 4.58~3.4 4.6~3.4
Maximum power (kW) 3,202 4,004 5,005 6,01
Maximum current (A) 7,5 10,1 12,5 16,1
Electricity supply 220~240V / 50Hz
Protection IPX4
Heating temperature range 15°C~40°C
Cooling temperature range 8°C~28°C
Operating temperature range -10°C~43°C
Unit dimensions L x W x H (mm) 950 x 355 x 650
1055 x 395 x 703
Unit weight (kg) 56 60 65 73
Sound pressure level at 1 m (dBA)
(3)
40~48 41~50 42~51 43~52
Sound pressure level at 10 m (dBA)
(3)
21~29 23~31 24~32 24~33
Hydraulic connection (mm) PVC 50mm
Heat exchanger PVC tank and titanium heating coil
Min. water ow rate (m³/h) 3.3 / 8.5 4.4 / 10.3 5.2 / 12.5 7.1 / 16.1
Compressor Mitsubishi Mitsubishi Mitsubishi Mitsubishi
Compressor type Twin Rotary Twin Rotary Twin Rotary Twin Rotary
Refrigerant R410A
Refrigerant content (kg) 0.9 1.05 1.2 1.6
GWP 2088 2088 2088 2088
CO2 equivalent 1.88 2.19 2.51 3.34
Load loss (mCE) 1,1 1,1 1,1 1,2
Max. pool volume (m
3
)
(4)
≤60 ≤75 ≤95 ≤130
Remote control Wired backlit LCD monitor screen
Mode Heating / Cooling
2.3 Technical specications
2. Description
The technical specications of our heat pumps are provided for information purposes only. We reserve the right to make changes without prior notice.
1
Ambient air temperature
2
Initial water temperature
3
Noise at 1 m, at 4 m and at 10 m in accordance with Directives EN ISO 3741 and EN ISO 354
4
Calculated for an in-ground private swimming pool covered with a bubble cover.

Related product manuals