14
Making a hydraulic connection with the By-Pass kit
Step 1: Take the necessary steps to cut your pipes.
Step 2: Make a straight perpendicular cut through the PVC pipes with a saw.
Step 3: Assemble your hydraulic circuit without connecting it in order to check that it perfectly ts your
installation, then dismantle the pipes to be connected.
Step 4: Chamfer the ends of the cut pipes with sandpaper.
Step 5: Apply stripper to the ends of the pipes to be connected.
Step 6: Apply the adhesive in the same place.
Step 7: Assemble the pipes.
Step 7: Clean off any adhesive remaining on the PVC.
Step 8: Leave to dry for at least 2 hours before putting the hydraulic circuit into water.
3.6 Hydraulic connection
3. Installation
WARNING: Installation must be carried out by a qualied engineer.
This section is provided for information purposes only and must be checked and adapted if
necessary according to the actual installation conditions.
WARNING: Do not run water through the hydraulic circuit for 2 hours after applying the adhesive.
By-Pass assembly
The heat pump must be connected to the pool by
means of a By-Pass assembly.
A By-Pass is an assembly consisting of 3 valves that
regulate the ow circulating in the heat pump.
During maintenance operations, the By-Pass permits
the heat pump to be isolated from the system without
interrupting your installation.
TOWARDS THE POOL
Open valve
Half-open valve
FROM THE POOL