32 | EN
Code Descripon Soluon
1
Compressor over-
current
1. The compressor is temporarily overloaded (for example, liquid
compression).
2. The program does not match the compressor.
3. The U, V, and W lines of the compressor are inversely connected, and the
compressor reverses.
4. Compressor wear (lack of oil, liquid compression lead to wear cylinder
block).
2
Compressor out of
step
1. The compressor is temporarily overloaded (for example, liquid
compression).
2. The program does not match the compressor.
3. The compressor start pressure dierence is too high and low.
8
Compressor phase
loss
1. Cables U, V, and W of the compressor are missed or improperly
connected.
2. The program does not match the compressor.
3. The compressor starts too high and low pressure dierence.
16
DC voltage is too
low
1. Check whether the AC voltage is abnormal.
2. AC power is suddenly cut o, and the DC voltage will be too low when
the converter capacitor is le for the chip to work.
32
DC voltage is too
high
Check whether the AC voltage is abnormal.
257
Communicaon is
abnormal
1. Check whether the communicaon cable is improperly connected.
2. Check whether the baud rate and communicaon address code are set
according to the communicaon protocol.
3. Replace the driving board for tesng.
258
AC phase loss or CT
is disconnected
1. The current transformer on the driving board is damaged during
transportaon.
2. Check whether the current transformer is improperly inserted during
producon.
3. The AC current at the frequency above 40Hz is very small, resulng in
abnormal detecon of the current transformer.
260
AC over-current
or compressor
overpower
1. AC overcurrent (currently available for external models with a separate
lter board), the load is suddenly too large to reduce the frequency.
2. Compressor overpower (combined plate, three-phase 380V, no single
lter plate model) the load is suddenly too large to reduce the frequency
too late.
3. Compressor overpower (combined plate, three-phase 380V, models
without separate lter plate) The compressor starts too high and low
pressure dierence.
Error codes 1 to 128 are displayed in priority. Error codes 257 to 384 are only displayed if the
previous ones do not appear.
If two or more error codes appear at the same me, then the error codes accumulate.
For example, if codes 8 and 16 occur at the same me, the display shows 24.