MAINTENANCE
Use the Maintenance Schedule to keep your generator in the best operating condition. Maintenance includes
checking the condition of a part used in the generator, as well as cleaning, adjusting, or replacing a part. The oil
should be changed after the first 4 to 6 hours of operation to remove any manufacturing debris or contamination.
Use genuine POWERHOUSE® parts or the equivalent.
The use of replacement parts which are not of equivalent quality may damage the generator or void the
warranty. Find a Service Center
i
When repairing or replacing the components of the emission control system, make sure to use
OEM EPA-compliant components. For details, see APPENDIX A - Emission Control System.
Maintenance Schedule
PART MAINTENANCE
REGULAR SERVICE PERIOD
Log hours of operation to determine proper maintenance.
Each Use
1st Month
or 4 to 6 Hours
Every 3 Months
or 50 Hours
Every 6 Months
or 100 Hours
1x per Year
or 300 Hours
Engine oil
Check O
Change O O
Air lter element
Check O
Clean
O
*
Spark plug
Clean / Adjust O
Replace
The spark plug will last longer in a generator that runs at varying loads. If you always run
the generator at the same load, you will need to replace the spark plug more frequently.
Spark arrestor Clean O
12V battery Clean / Charge
Charge monthly during long term storage.
Check terminals for corrosion monthly, clean as needed.
Expected battery life is 2 years, but can be aected by operating environment.
Fuel lter ◊
Check O
Replace
O
*
Fuel tank &
strainer ◊
Clean
O
*
Fuel injector ◊ Clean Add fuel injector cleaner to the fuel tank every 100 hours.
Fuel line ◊ Check Every 2 years (replace as necessary)
Valve clearance ◊ Check / Adjust O
* Service more frequently when used in dusty areas. These items should be serviced by an authorized dealer unless the owner has the proper tools and
is mechanically procient. See the Service Manual. The maintenance of these parts is covered in the Service Manual.
SERVICE PERIOD FOR OIL CHANGES NORMAL OPERATING TEMPERATURE
Normal –100 hr 77°F (25°C)
95 hr 86°F (30°C)
85 hr 95°F (35°C)
70 hr 104°F (40°C)