17
Table of Contents To navigate between hyperlink topics using a keyboard, select ALT+◄ or ALT+►.
STARTUP & SHUTDOWN
You can start the generator using any of the following methods:
Ignition Key Startup at the control panel
Remote Startup using the remote switch at the control panel and the remote key fob
Recoil Pull Startup using the recoil handle on the right side of the generator
Ignition Key Startup
Before using the generator, read and comply with all Safety Alerts and Icons.
Before starting the generator, make sure the 12V battery is fully charged. The generator requires at least 10.5
cranking volts of battery charge to provide power for startup components and sensors.
To start the generator with the ignition key:
1. On the control panel, verify that the remote switch is in the OFF position.
2. Insert the ignition key, then turn and hold the ignition key in the START position. The LCD on the control panel illuminates.
i
Once the ignition switch is ON, if you do not start the generator within 30 seconds, the LCD dims to conserve
battery power.
If the engine does not start within 15 seconds, stop turning the key for 5 seconds before trying it again.
START
The LCD shows output voltage when the generator is ready for use.
3. Connect your appliance to the generator's output receptacle.
i
Make sure that appliances are in good working condition and that the combined electrical rating of all
connected appliances does not exceed that of the generator (2400W max). If you don't know the watts for your
appliance, multiply the amperage by the output voltage. For example: 20A x 120V = 2400W.
4. Turn your appliance on.
Shutdown
|
Clearing an Overload Condition
| Parallel Mode Operation