To navigate between hyperlink topics using a keyboard, select ALT+◄ or ALT+►.
34
Table of Contents
Changing the Engine Oil
Engine oil capacity: 15.6 fl oz (460 ml)
Change the oil after the first 4 to 6 hours of operation to remove any manufacturing debris or contamination, and as
recommended in the Maintenance Schedule. Change the oil while the generator is OFF and the engine is still warm to
assure rapid and complete draining.
Use a premium quality, 4-stroke engine oil that is a certified API grade SF/SG or better.
• For environmental temperatures above 32°F (0°C), use SAE 10W-30 viscosity oil.
• For environmental temperatures below 32°F (0°C), use SAE 0W-30 or 0W-40 viscosity oil, preferably synthetic.
!
▲ Use caution when draining hot oil from an engine that can cause severe burns.
▲ Running the engine with insufficient oil can cause serious engine damage.
To change the engine oil:
1. On the left side of the generator, remove the screw and the Maintenance Access Door.
2. Remove the dipstick from the oil reservoir.
3. Insert the oil drain pipe (included with the generator) into the oil reservoir.
4. Tilt the generator to drain the dirty oil into a container. Be sure to allow time for the oil to drain completely.
Please dispose of used motor oil in a manner that is compatible with the environment and local disposal
regulations. Do not throw it in the trash or pour it on the ground.