24
DigiMod PFC2 - PFC4 | SERVICE MANUAL
INDEX
Switch the input signal off.
Switch the module on.
Measure the voltage at the TEMPMON pin
2.75 V
DC
< V
TEMPMON
< 2.85 V
DC
(no input signal)
Switch the input signal on.
After approximatively 3 minutes the module’s fans start
spinning.
Measure the voltage at the TEMPMON pin
2.20 V
DC
< V
TEMPMON
< 2.30 V
DC
(with input signal)
Thermal Limit
VOUTMON Voltage
IOUTMON Voltage
Measure the voltage at the VOUTMON pin:
5.40 V
peak
< V
VOUT2MON
< 5.70 V
peak
Measure the voltage at the IOUTMON pin:
2.85 V
peak
< V
IOUT2MON
< 3.10 V
peak