Product Owner's Manual: Important Safety Instructions 7
Electrical Recommendations: 120 V and
240 V Treadmills
Note:
You should have received a power cable that meets your local
electrical code requirements along with the equipment. Precor
treadmills must be connected to a 20 amp individual branch circuit
that can be shared only with one PVS. If you need additional help
with the power connections contact your Precor authorized dealer.
This is a recommendation only. NEC (National Electric
Code) guidelines or local region electric codes must be followed.
Important: An individual branch circuit provides a hot conductor
and neutral conductor to a receptacle. The conductors must not
be looped, "daisy-chained", or connected to any other conductors.
The circuit must be grounded according to NEC guidelines or
local region electric codes.
Figure 2: North American 120-volt, 20-amp power receptacle
Figure 3: North American 240-volt, 20-amp power receptacle