DS600 Non-Ferrous Double Sheet Detector
This document is confidential and proprietary. No part of this document may be disclosed in any manner
to a third party without the prior written consent of Prime Controls, Inc.
202177 27 Revision M
7 ELECTRICAL SPECIFICATIONS
Supply Voltage: 24 volts DC plus or minus 10%
Supply Current: 200 mA plus sourcing output load
Inrush Current at Startup: 300 mA
CAL and RESET Max Input Voltage: 30V
CAL and RESET Input Impedance: 5K ohms
IN REF Max Voltage: 26 Volts
SEL REF Max Voltage: 26 Volts
OUT REF Max Voltage: 26 Volts
Sourcing Outputs: On voltage: OUT REF (See I/O Wiring, p. 4)
Off voltage: 0 volts
Max current: 50 mA
Sinking Outputs: On voltage: 0 volts
Off voltage: OUT REF (See I/O Wiring, p. 4)
Max current: 50 mA
Output Overload Protection: 50 mA self-resetting thermal fuse
Input and Output Transient Protection: 30 volt transient absorber.
Probe Cable Length: 30m maximum
NET input and NET output: Isolated RS485 2W, 38400 baud, RTU mode
Users selectable termination