DS600 Non-Ferrous Double Sheet Detector
This document is confidential and proprietary. No part of this document may be disclosed in any manner
to a third party without the prior written consent of Prime Controls, Inc.
202177 1 Revision M
1 SYSTEM COMPONENTS
1.1 Control Module
The DS600 control module, being sealed, offers flexibility in mounting. Once installed, the
system can be quickly and easily brought on-line. Calibration is achieved through the simple
press of a push-button switch on the front panel or a remote contact closure connected to the
CAL terminal. System status and faults are reported on a four digit numeric display and are
signaled through the FAULT output that may be connected to a PLC or system controller.
The DS600 control module comes in three variations which differ in available features. The
three variations are designated DS600 (basic), DS600P, and DS600PC. All variants share a
common footprint and utilize the P80T30 probe. All models offer the following features:
Sealed polycarbonate enclosure
Four digit digital display
LED indicator for ACCEPT
LED indicator for REJECT
User selection of the gauging mode, single/double or part present
User selection of the response to a no-metal condition, REJECT or ACCEPT
Front panel pushbutton switch to invoke calibration and parameter adjustment
Isolated sinking or sourcing logic inputs, CAL and RESET
Remote initiation of calibration through the CAL input
Remote reset of the latched REJECT output through the RESET input
Isolated sinking or sourcing logic outputs, ACCEPT, REJECT, FAULT and AUX
One and two point thickness calibration
At least one non-volatile calibration memory
Single/Double gauging tolerance parameter HtoL, adjustable through the front panel
Part present gauging tolerance parameter toL, adjustable through the front panel
The DS600P control module offers these additional features:
“Under” condition sensing with tolerance set through parameter Ltol
Delay of under condition reporting through delay parameter Udly
Up to eight non-volatile calibration memories
Selection of up to 8 calibration memories through the front panel parameter SEL (1-8)
Logic inputs SEL0, SEL1, SEL2, and ENABLE for selection of the calibration memory
from a remote switch or controller
The DS600PC control module offers these added features:
Up to 64 non-volatile calibration memories
Selection of up to 64 calibration memories through the front panel parameter SEL (1-64)
Selection of the first eight calibration memories through terminals SEL0, SEL1, SEL2
and ENABLE
Modbus communications through an M12 connector providing access to:
o The DIP switch settings
o 64 calibration memories, select and read-back
o The gauging signal value
o The four digit display information as text