100962 G PUBLICATION DATE 24 JUN 2008.DOC PROGRAMMING MANUAL 51
T THE COOLDOWN SEQUENCE
After a Hot wash you can program a Cool-down Sequence to avoid the temperature shock and
shrinking of the garments.
The drain step after the Hot wash must be put on NO DRAIN.
No inlets are programmable for :
- the Top Soap hopper machines : inlet 6 is the standard inlet.
- the Front Soap hopper machines : inlet 2 is the standard inlet.
The water level can‘t be programmed as the process of adding and draining water doesn’t allow
this.
ATTENTION
!
DO NOT PROGRAM A DRAIN SEQUENCE BEFORE A COOLDOWN SEQUENCE
°C : degrees Celsius
°F : degrees Fahrenheit
The temperature can be programmed between 1°C and
60°C.
60°C is the suggested default value.
Insert the desired temperature. Press the ENTER button for
confirmation.
The suggested drum speed value depends of the machine
type.
Check the corresponding table paragraph 3.4.
The drum speed value can only be programmed within
certain limits.
Insert the desired speed value. Press the ENTER button for
confirmation.
Only available on washing machines with both : a normal
Open and a normal Closed Drain valve.
As water will be drained at the Cool-down Sequence, it must
be possible to select the drain valve 1 or 2.
The default Drain valve is Drain valve 1.
Select the desired Drain Valve by pressing the
ARROW LEFT or RIGHT button.
Press the ENTER button for confirmation.
Prewash
|
Wash
|
Cooldown
|
Rinse
|
Final Rinse
|
Soak
|
Flush
|
S
p
ra
y
|
No wash
P:Pr XX Step XX
Temp : 60 °C
P:Pr XX Step XX
RPM : _ _
P:Pr XX Step XX
Drain valve : 1
1 | 2 | 1+2
!