52 PROGRAMMING MANUAL 100962 G PUBLICATION DATE 24 JUN 2008.DOC
The wash motor ON time can be programmed between 0 and
99 seconds.
The wash motor OFF time can be programmed between 3
and 99 seconds.
The suggested default values can be adapted in the
Initialisation menu.
Standard wash motor ON time of 12 seconds and a wash
motor OFF time of 3 seconds is recommended for normal
wash. A wash motor ON time of 3 seconds and a wash motor
OFF time of 12 seconds is recommended for a gentle wash
(woollens).
Insert the wished ON – OFF times. Press the
ENTER button for confirmation.
FS120, MB90, MB140, MB180 : 12Sec ON and 5Sec OFF
The Cool-down Sequence can be programmed between 0
and 99.5 minutes in steps of 0.5 minutes.
The default time is 7 Minutes.
The programmed time = the time needed to decrease the
water temperature.
Once the programmed temperature has been reached, the
next Sequence will be started.
Programming a time of 0 minutes : the Cool-down will not be
functional (cfr No Wash)
Insert the desired Cool-down time. Press the
ENTER button for confirmation.
Attention
!
If a short time is programmed, the water temperature will
decrease fast.
Recommendation !
Programming 1 minute for each 3°C temperature drop
For a hot wash of 90°C and a Cool-down Sequence of 60°C,
a time of about 30°C/3°C = 10 Minutes should be programmed
for the Cool-down Sequence.
When a signal is programmed, a pause will be introduced at
the end of the Wash Step. This allows the operator to add
soap for the next step. To alert the operator that the program
has been interrupted, a buzzer signal will be activated.
By pressing the START button, the program will continue.
Yes : Signal enabled.
No : Signal disabled.
Press the ENTER button for confirmation.
GOTO °
P:Pr XX Step XX
Time : 7 Min
P:Pr XX Step XX
On Time : _ _ Sec
P:Pr XX Step XX
Off Time: _ _ Sec
P:Pr XX Step XX
Signal : No
!