540876_A_PUB_DATE_1_FEB_2012.DOC PROGRAMOVACÍ MANUÁL 13
INTRODUCTION
Programming the Drain sequence :
After programming the Wash sequence, next program the Drain/Extraction sequence.
DRAIN
EXTRACTION
No DRAIN
STATIC DRAIN
REVERSING DRAIN
Then program all the related functions of the Drain/Extraction sequence.
The available functions are :
Sequence Time ( length of step )
Speed
Drain valve 1 - 2
As you will notice it’s also possible to skip a sequence between two other sequences by
programming No WASH or No Drain.
Example : The No drain sequence should be programmed between a wash and a cool-down
sequence.
ATTENTION!
A MORE DETAILED EXPLANATION FOR THE SPECIFIC SEQUENCES CAN BE FOUND IN CHAPTER 5.
The Tumble sequence :
The wash cycle will always end with the Tumble sequence.
The tumble sequence takes 30 Seconds, then the program is finished and the door can be opened.
The Tumble sequence cannot be skipped.
!