14 PROGRAMOVACÍ MANUÁL 540876_A_PUB_DATE_1_FEB_2012.DOC
3.5. PROGRAMMING THE FUNCTIONS
Limits
To ensure the correct functionality of the washing machine you have to program values within
certain limits.
If you program a value that falls below the minimal or above the maximal programmable limit
then the new value will not be accepted and the previous value stays valid.
Programming the Water Temperature
Limits
- Minimum value : 1 °C
- Maximum value : 45°C for the PREWASH and SOAK and 92°C for the WASH sequence.
- For RINSE, FINAL RINSE and SPRAY no Temperature can be programmed.
Programming the Water Inlet valves
Depending on the programmed temperature the water inlet valves are suggested.
While the tub is filling with water, the computer controls the water temperature. By switching on
and off the hot and cold water inlet valves the correct water temperature is obtained.
For machines with a Top Soap Dispenser you have to consider that by programming the water inlet
valves, at the same time, you are also selecting the soap Box at which the soap must be added.
If you want to program a wash sequence with :
- Cold Water : only Cold Inlet Valves must be programmed
- Warm or Hot water : Cold and Hot Inlet Valves must be programmed
The cold water inlet valves
Inlet Valve 1 corresponds with soap box for a Prewash
Inlet Valve 2 corresponds with soap box for a Wash - detergent
Inlet Valve 3 corresponds with soap box for a Wash - liquid soap
Inlet Valve 4 corresponds with soap box for a Final Rinse
Inlet Valve 7 is a direct Inlet Valve and speeds up the water fill process
The hot water inlet valves
Inlet Valve 5 corresponds with soap box for a Prewash
Inlet Valve 6 corresponds with soap box for a Wash - detergent
Inlet Valve 8 corresponds with soap box for a Wash - liquid soap
How to select inlet valves : EXAMPLE
For a Prewash : Programmable temperature: 1 - 45°C
Inlet Valve 1 (cold) and/or 5 (hot) soap box for a Prewash
and/or 7 (cold) direct Inlets
For a Wash : Programmable temperature: 1 - 92°C
Inlet Valve 2 (cold) and/or 6 (hot) soap box for a Wash - detergent
and/or 7 (cold) direct Inlets
For a Rinse : Inlet valves 1+2+7 (cold) No detergent is added
For a Final Rinse : Inlet valve 4 soap box for a Final rinse
and/or 7 (cold) direct inlets