540876_A_PUB_DATE_1_FEB_2012.DOC PROGRAMOVACÍ MANUÁL 73
TROUBLESHOOTING
Failure message Failure Action Fault occurrence
E83
Cycle Fail
No successful wash
cycle termination
Info that the wash cycle
has to be repeated.
Abnormal Cycle Termination
(Traceability only)
E85
RTC Low Batt
Real Time Clock, No
Battery or battery low
power
For Info only. End cycle
(Traceability only)
E300-
E353
Mits Err
Specific Mitsubishi
Inverter Alarm
Full stop + safety time Whole cycle
E500-
E525
Memory Err
Memory Error Full stop + safety time Any time
E550
TRACEYBILITY
Write
Internal memory Error
data for traceability
For Info only Traceability function, whole
cycle
E551
TRACEYBILITY
Full
Internal Traceability
memory is full
For Info only Traceability function, whole
cycle
E600-
E628
Softw Err
Software Error Full stop + safety time Any time

Table of Contents