EasyManua.ls Logo

ProLights UNICO - Troubleshooting; Error Information

ProLights UNICO
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UNICO
26
Message Description
Lamp Startup Fail It appears when there is no lamp or some wires are damaged.
Temperature Sense Error It appears when temperature check board is damaged.
Lamp Too Hot Power O
It appears when temperature is detected higher than 110°C. Check if the unit is
properly ventilated, or fans or temperature check board may is damaged.
Lamp Too Hot Low Power
It appears when temperature is detected higher than 105°C, the unit will run on a
low power level
Maintenance Fixture
It appears when the maintenance remaining time becomes 0S, please enter menu
mode and reset the time.
Lamp On Over 700 Hour It appears when the lamp has been on over 700 hours, please turn o the lamp.
Memory Initial Fail It appears when the memory IC is damaged.
CPU‐B Error, CPU‐C Error, CPU‐D Error They appear when board P.C or some wires are damaged.
Pan Reset Error, Dimmer Reset Fail, ecc.
They may appear when turning on or resetting the unit, for some parts such as
board P.C are damaged. Please contact the qualied maintenance.
4.3 TROUBLESHOOTING
4.4 ERROR INFORMATION
Contact an authorized service center in case of technical problems or not reported in the table can not be
resolved by the procedure given in the table.
Problems Possible causes Checks and remedies
Fixture does not light up
• No mains supply
• Faulty fuse
• Incorrect setting DMX
• Lamp exhausted or defective
• Check the power supply voltage
• Replace a burnt-out fuse by one of the same
type only
• Check setting DMX
• Replace the lamp
General low light intensity
• Dirty lens assembly
• Misaligned lens assembly
• Clean the xture regularly
• Install lens assembly properly
Fixture does not power up
• No power
• Loose or damaged power cord
• Faulty internal power supply
• Check for power on power outlet
• Check power cord
• Replace internal power supply
Fixture does not respond to DMX
• Wrong DMX addressing
• Damaged DMX cables
• Bouncing signals
• Check control panel and unit addressing
• Check DMX cables
• Install terminator as suggested