Page 38
7.7 Troubleshooting
CAUTION!
Only authorised electricians are permitted to perform troubleshooting operations on the
opened control cabinet and replace components!
Warning threshold undershot
Indication: Arrow pointing down
Safety threshold undershot
Indication: Two flashing arrows pointing down
The remaining clear flushing time is shown
(2 squares flash instead of the seconds)
Fault: Safety threshold undershot (after maximum clear flushing time has elapsed)
Error message: UV sensor
Confirm error message with ENTER key
Press CHANGE key to assume emergency mode (see 4.3.20)
Emergency mode: Safety threshold undershot
System continues operating in emergency mode
Possible cause Coating on lamp protective tube
Remedy Clean lamp protective tube
Possible cause Deterioration of UV transmission of water to be treated
Remedy Improve water quality
Possible cause UV lamp at end of useful life
Remedy Install new UV lamps
Possible cause Incorrect lamp current
Remedy Operate with standard current
Possible cause Sensor not calibrated correctly
Remedy Recalibrate sensor
Fault: Lamp failed
Error message: xx lamp defective
Confirm error message with ENTER key
Press CHANGE key to assume emergency mode (see 4.3.20)
Emergency mode: Lamp failed
System continues operating in emergency mode
Possible cause Lamp xx defective
Remedy Install new UV lamps
Possible cause Incorrect lamp current
Remedy Operate with standard current
Possible cause Ballast defective
Remedy Replace ballast
IMPORTANT!
The number of failed UV lamps is indicated.
If more than one UV lamp has failed, the individual lamps can be queried by pressing the
UP and DOWN key.
Emergency mode
UV sensor
Fault
xx lamps defective
Lamp #xx
Emergency mode
xx lamps defective
Lamp #xx
Maintenance
55.0 W/m
2
10 h Operation
20 ON/OFF
40.0 W/m
2
Clear flushing
Time 00:11
Fault
UV sensor

Table of Contents