EasyManua.ls Logo

ProMinent Dulcodes R - Troubleshooting; Fault: Safety Threshold Undershot; Fault: Lamp Failed

ProMinent Dulcodes R
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 38
7.7 Troubleshooting
CAUTION!
• Only authorised electricians are permitted to perform troubleshooting operations on the
opened control cabinet and replace components!
Warning threshold undershot
Indication: Arrow pointing down
Safety threshold undershot
Indication: Two flashing arrows pointing down
The remaining clear flushing time is shown
(2 squares flash instead of the seconds)
Fault: Safety threshold undershot (after maximum clear flushing time has elapsed)
Error message: UV sensor
➤ Confirm error message with ENTER key
➤ Press CHANGE key to assume emergency mode (see 4.3.20)
Emergency mode: Safety threshold undershot
➤ System continues operating in emergency mode
Possible cause Coating on lamp protective tube
Remedy ➤ Clean lamp protective tube
Possible cause Deterioration of UV transmission of water to be treated
Remedy ➤ Improve water quality
Possible cause UV lamp at end of useful life
Remedy ➤ Install new UV lamps
Possible cause Incorrect lamp current
Remedy ➤ Operate with standard current
Possible cause Sensor not calibrated correctly
Remedy ➤ Recalibrate sensor
Fault: Lamp failed
Error message: xx lamp defective
➤ Confirm error message with ENTER key
➤ Press CHANGE key to assume emergency mode (see 4.3.20)
Emergency mode: Lamp failed
➤
System continues operating in emergency mode
Possible cause Lamp xx defective
Remedy ➤ Install new UV lamps
Possible cause Incorrect lamp current
Remedy ➤ Operate with standard current
Possible cause Ballast defective
Remedy ➤ Replace ballast
IMPORTANT!
• The number of failed UV lamps is indicated.
• If more than one UV lamp has failed, the individual lamps can be queried by pressing the
UP and DOWN key.
Emergency mode
UV sensor
Fault
xx lamps defective
Lamp #xx
Emergency mode
xx lamps defective
Lamp #xx
Maintenance
↓↓
↓↓
↓ 55.0 W/m
2
10 h Operation
20 ON/OFF
↓↓
↓↓
↓
↓↓
↓↓
↓ 40.0 W/m
2
Clear flushing
Time 00:11
Fault
UV sensor

Table of Contents