Tab. 16: Pump types 1002
2
, 2502, 1006, 0613, 0417
Mains connection (V) 100 115 200 230 500
Max. current con‐
sumption*** (A)
3.0 2.7 1.8 1.8 0.6
Effective power con‐
sumption
1
(A)
0.70 0.70 0.33 0.41 0.14
Mean power consump‐
tion (W)
35 35 35 35 35
Fuse item 65* value
(A)
2.5T 2.0T 1.25T 0.8T 0.63
Fuse item 66** value
(A)
0.16T 0.16T 0.16T 0.16T -
Tab. 17: Pump types 2505, 1310, 0814, 0430, 0260
Mains connection (V) 100 115 200 230 500
Max. current con‐
sumption*** (A)
4.1 3.6 2.2 2.5 1.1
Effective power con‐
sumption
1
(A)
0.95 0.84 0.47 0.53 0.25
Mean power con‐
sumption (W)
47 47 47 47 47
Fuse item 65* value
(A)
3.15T 2.5T 1.6T 1.25T 1.25
Fuse item 66** value
(A)
0.16T 0.16T 0.16T 0.16T -
* special fuse with high switching capacity: only use original fuse
** use only original fuse
*** effective value during a stroke
1
obtained by averaging over several strokes at the maximum
stroke rate
2
for PP4 material version
.
Fuse order numbers, see “Ordering information for fuses” chapter.
CAUTION!
Only the effective power consumption is specified
on the nameplate.
Technical data