EasyManua.ls Logo

ProMinent EXtronic EXBb - Page 53

ProMinent EXtronic EXBb
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Tab. 16: Pump types 1002
2
, 2502, 1006, 0613, 0417
Mains connection (V) 100 115 200 230 500
Max. current con‐
sumption*** (A)
3.0 2.7 1.8 1.8 0.6
Effective power con‐
sumption
1
(A)
0.70 0.70 0.33 0.41 0.14
Mean power consump‐
tion (W)
35 35 35 35 35
Fuse item 65* value
(A)
2.5T 2.0T 1.25T 0.8T 0.63
Fuse item 66** value
(A)
0.16T 0.16T 0.16T 0.16T -
Tab. 17: Pump types 2505, 1310, 0814, 0430, 0260
Mains connection (V) 100 115 200 230 500
Max. current con‐
sumption*** (A)
4.1 3.6 2.2 2.5 1.1
Effective power con‐
sumption
1
(A)
0.95 0.84 0.47 0.53 0.25
Mean power con‐
sumption (W)
47 47 47 47 47
Fuse item 65* value
(A)
3.15T 2.5T 1.6T 1.25T 1.25
Fuse item 66** value
(A)
0.16T 0.16T 0.16T 0.16T -
* special fuse with high switching capacity: only use original fuse
** use only original fuse
*** effective value during a stroke
1
obtained by averaging over several strokes at the maximum
stroke rate
2
for PP4 material version
.
Fuse order numbers, see “Ordering information for fuses” chapter.
CAUTION!
Only the effective power consumption is specified
on the nameplate.
Technical data