17 Ordering information for fuses
Even if the pump drive is not to be opened under
any circumstances, we would recommend:
keeping suitable fuses in stock so that the service
team has them to hand immediately if needed.
Tab. 18: Fuse item 65
Voltage Pump types Fuse data Order no.
100 V 1000.1601, 1201, 0803, 1002, 0308 5x20 T 1.0A (1.5kA) 732409
100 V 2502,1006,0613,0417,1002HV 5x20 T 2.5A (1.5kA) 732413
100 V 2505,1310,0814,0430,0260 5x20 T 3.15A (1.5kA) 732414
115 V 1000.1601, 1201, 0803, 1002, 0308 5x20 T 630 mA (1.5kA) 732407
115 V 2502,1006,0613,0417,1002HV 5x20 T 2.0 A (1.5kA) 732412
115 V 2505,1310,0814,0430,0260 5x20 T 2.5 A (1.5kA) 732413
200 V 1000.1601, 1201, 0803, 1002, 0308 5x20 T 400mA (1.5kA) 732405
200 V 2502,1006,0613,0417,1002HV 5x20 T 1.25A (1.5kA) 732410
200 V 2505,1310,0814,0430,0260 5x20 T 1.6A (1.5kA) 732411
230 V 1000.1601, 1201, 0803, 1002, 0308 6.3x32 T 315 mA 500V
(1,5kA)
732404
230 V 2502,1006,0613,0417,1002HV 6.3x32 T 800 mA 500V
(1,5kA)
732408
230 V 2505,1310,0814,0430,0260 6.3x32 T 1.25 A 500V (1,5kA) 732410
500 V 1000.1601, 1201, 0803, 1002, 0308 6.3x32 T 315 mA 500V
(1,5kA)
732371
500 V 2502,1006,0613,0417,1002HV 6.3x32 T 630 mA 500V
(1,5kA)
732372
500 V 2505,1310,0814,0430,0260 6.3x32 T 1.25 A 500V (1,5kA) 733150
Tab. 19: Fuse item 66
Voltage Pump types Fuse data Order no.
100 ... 230 V all 5x20 T 160 mA (35A) 712048
Fuses
Ordering information for fuses
66