72-910-16 Rev. N
Page 39 of 43
Inputs receptacles or hock-ups for signals delivered to the controller
Interval the amount of time between bleed events
Isolated Input an input (analog or digital) that is electrically isolated from main power supply and its ground
(ISO) Isolation Valves general term that refers to valves in the system used to isolate various components of the
system from the main flow
Jumper a wire connector (shunt) that connects two (2) points
LED abbreviation for Light Emitting Diode
Limit Timer also referred to as lockout timer or feed limit timer, it limits the amount of time output is activated
Line Voltage voltage equivalent to outside source voltage to the controller
Lockout intentionally preventing bleed or other functions of the system
Low Current 4 mA signal
Menu Map printed document supplied with controller illustrating all menu item locations
Metering Pump see chemical feed pump
Micro Siemens unit of measure of conductivity expressed as S/CM
Outputs receptacles or hook-ups for signals originated at the controller
Overfeed a condition in which the quantity of an ingredient dispersed into the system exceeds the amount desired
Percent Post Bleed refers to the amount of time as a percentage of bleed time that chemical feed pumps are
activated when bleed down is deactivated
Percent Timer also referred to as a cycle timer that runs continuously that activates an output to run as a percent
of total cycle time
Pre Bleed refers to the time bleed is executed before biocide feed
Program Parameters the user programmed settings that determine how the controller responds to conditions of
the system under control
Prompt a curser used to indicate the active menu line
Pulse the action of a water meter that when equipped with a contact head, can generate a dry contact closure that
can be read by the controller
Pulse Timer a feature of the controller in which a timer accepts pulses from a water meter to actuate a chemical
feed pump
Relay Indicators lights (LED’s) located on the face of the control panel that indicate the status of individual
relays
Sample to obtain a quantity of water for test purposes,
Sample Cock see Sample Valve
Sample Line a line through which a portion of the system water flows, where probes and other monitoring
devices are located controlled with isolation valves
Sample Valve small valve on the flow assembly that provides user a means to drain small quantities of water
from the system for testing
Security Code a code that can be entered by the user when configuring the system to secure access to the
controller settings
Probe a device connected to the controller which monitors or measures a characteristic value in the water, like the
conductivity
Sensor see Probe
Set point the user determined value within a monitored range at which the controller initiates action (e.g.,
activates a relay)
Set point Differential also referred to as dead band or hysteresis; the offset applied to a set point to prevent
chattering of an output relay around a set point
Soft Keys Buttons on front panel used to input information
Solenoid an electromagnetically controlled switch