Page 109 
RATIOMETRIC 
If the flow calculation is to be ratiometric P702 = 2 the flow will be 
calculated using the formula: q= q
cal
C
e
/C
ecal
(h
e
/h
ecal
)
1.5
 
Where:  q        =   flowrate              
q 
cal
    
= flowrate at maximum head P705  
Ce   = discharge coefficient calculated by Flow 3 P723 
Ce
cal
  = discharge coefficient at maximum head   
he      = effective head           
he
cal
   = effective head at maximum head