Matrix User Guide
Page 52 RINS915-2
CHAPTER 9: EVENT LOG TABLES
The event log can be viewed on the Matrix keypad using user mode function 13 as described on page 27.
9.1 Icon Keypad Log Table
This table can be used to decrypt the log messages on the Icon keypad into meaningful information. All icons
shown with a ñsymbol, indicate that the icon is flashing. z = steady. á= flashing.
Keypress
1st 2nd
Icon Description
Alarms
oo
z
Entry / Exit timer expired
00 - 32
ï
PA zone activated, number signifies zone (00 = keypad)
00 - 32
î
Fire zone activated, number signifies zone (00 = keypad)
t
î
Fire activated from a keypad
t
å
Fire detector input tamper
01 - 32
á
Burglary on zone, number signifies zone
01 - 32
å
Tamper on zone, number signifies zone
00 - 32
Medical alarm, number signifies zone (00 = keypad)
Tampers
f 01 à
Global tamper loop broken
f 02 à
Bell tamper loop broken
f 04 à
Plug on zone expander board not present
f 06 à
Remote device missing caused tamper
f 08 à
Keypress tamper
f 09 à
A Remote device has detected a tamper
p
Telephone line fail alarm
ef
01 - 99
à
Remote device Auxiliary tamper
2
nd
key refers to type/Id, 3
rd
key refers to device specific tamper:
3
rd
Key Meaning
01
Front tamper
02
Rear tamper (wall switch) – LCD only
03
Reserved
04
Reserved
05
Reserved
06
Reserved
07
Reserved
TAMPER LED
flashing indicates a
tamper activation.
TAMPER LED on
indicates a tamper
restore.
Restorals
01 - 32
|
Restore of Alarm
01 - 32
z
Zone restore
01 - 32
}
Fire restore
01 - 32
à
Global tamper restore
01 - 32 Medical restore