28 —FAQ AND TROUBLESHOOTING
RELEASE 1.0.1 —15 JULY, 2020
1.
2.
If these steps do not solve the problem i.e. the device still does not connect to the robot system please
raise a support request with at least the following details at our help desk portal:
The device serial number;
The robot system type and software version;
The installed qbrobotics URCap version;
The list of any other URCap installed in your robot;
The power supply configuration;
Any error reported in the UR logs tab;
Any additional info regarding what you were doing before the first failure;
8.2 The hand often disconnects while the robot is moving
8.2.1 Problem
When the robot is stopped, the user interface shows that the hand is properly connected and you can use
it with no problem for teaching grasp and set waypoints; the device status card (from either the
installation tab or the toolbar on e-Series robots) display data correctly.
However, when you start a robot program it often happens that it stops saying that the hand is not
connected any longer.
8.2.2 Solution
There may be a couple of reasons for this unexpected behavior:
Some cables are not properly connected or secured, and robot vibrations when it starts moving can
cause faults in the communication channel;
If you are powering the device from an external power source, there may be some electrical noise in
your network that is not properly filtered out.
WARNING:
Be aware that you need to leave the system without power for at least 30 seconds during
the power cycle.
Only in this way we can assure that the system has completely reset its electrical state.
WARNING:
Be aware that the device must not violate our warranty policy, cf. maintenance and
warranty(see Page 25), in order to ensure the best support service for our customer.
Please, do not forget to mention in your request if you have made forbidden hardware/
software modification to the device before/after the issue e.g. removing the glove cover is
forbidden, cf. forbidden actions(see Page 25). This will save you, and us, much time during the