SENSOR GROUPS
MOTION
GROUP
NAME
SUPERVISED
SCENARIO
17
Away- Instant Motion
Y
Active only when armed to “Away”, and trips instantly when motion is
detected. Does not trip if an entry/exit sensor is tripped first
15
Stay- Instant Motion
Y
Active in both “Stay” & “Away” modes, and trips instantly when motion is
detected. Does not trip if an entry/exit sensor is tripped first
35
Stay- Delay Motion
Y
Active in both “Stay” & “Away” modes. Triggers an entry delay when
motion is detected. Does not trip if an entry/exit sensor is tripped first
20
Away- Delay Motion
Y
Active when armed to “Away. Triggers an entry delay when motion is
detected. Does not trip if an entry/exit sensor is tripped first
25
Safety Motion
Y
This sensor does not report or trigger an alarm. This is a chime only sensor
when “Activity Monitoring” is active, regardless of panel status. Used for
medicine cabinets, storage, activity tracking, etc