SENSOR GROUPS
MOTION
GROUP
NAME
SUPERVISED
SCENARIO
43
Away- Instant, Stay-
Delay Motion
Y
Active in both “Stay” & “Away” modes. During Away mode, trips instantly
when motion is detected. Does not trip if an entry/exit sensor is tripped
first. During Stay mode, triggers an entry delay when motion is detected.
44
Away- Instant Interior
Motion
Y
Active only when armed to “Away”, and trips instantly when motion is
detected. Does not follow entry/exit delay rules and is always instant.
45
Away- Stay- Instant
Interior Motion
Y
Active in both “Stay” & “Away” modes. Trips instantly when motion is
detected. Does not follow entry/exit delay rules and is always instant.
*345 MHz motion sensors will have the option to change the “Loop” number to 1, 2 or 3. This will allow the sensor to be
programmed twice as 2 different zones where supported by the device.
*Power G Motion Detectors with Prefix 120, 122, 130, 140 and 142 offer additional functions such as High Traffic Shutdown
and Sensitivity Level. Motions with prefix 123, 126, 127, 128 and 129 offer High Traffic Shutdown only as an additional