Page #10 background imageLoading...
Page #10 background image
10
Connection via LAN
In order to activate the Ethernet port for communication, you must program a valid IP ADDRESS in the cash
register. This can be done in P-Mode by entering 97 on the TYPE key. The address consists of the three
values IP BASE ADDRESS, SUBNET MASK and DEFAULT GATEWAY.
The IP base address is the number of the register in the Ethernet network. Please note, that any address of
the network must be unique to avoid conflicts with other devices. The subnet mask is used to specify the
address range of the local network. It depends on the local network. In most cases it is set to 255.255.255.0
which means that the first 3 parameters specify the LOCAL network and the last the device in the network.
The Default Gateway is the address of the ROUTER when used. When the IP address is not on the LOCAL
network (checked by SUBNETMASK) this address will be used instead.
Please note that the programmed address must fit to the network settings in your PC. For further
information please check the additional programming guides or ask your local dealer and network
specialist.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the QUORION QMP 2000 series and is the answer not in the manual?

QUORION QMP 2000 series Specifications

General IconGeneral
BrandQUORION
ModelQMP 2000 series
CategoryCash Register
LanguageEnglish

Related product manuals