Warning - Risk of Explosion
Use only Explosion proof (Ex d) compound (due to > 2 [Liter] & IIB) cable glands or
conduit seals, depending on local requirements.
Warning - Risk of Explosion
Cables and cable glands for at least 80 [
◦
C] shall be used! Improper installation of cable
glands, conduits or stopping plugs will invalidate the Ex approval of the WaveGuide. The
use of stopping plugs on thread adapters is strongly advised against, as this may create
unsafe Ex d characteristics.
Warning - Risk of Explosion
All lid bolts must be fastened with a torque of 30 [N·m] or 22 [lbf·ft] to prevent danger of
explosion!
Caution
To comply with the IP66/IP67 requirements the blanking elements, threaded adapters,
cable glands and their interface with the housing must also comply with IP66/IP67
requirements.
Warning - Risk of Explosion
To avoid risk of dangerous amounts of electrostatic charging, clean the instrument only
with a damp cloth.
1.3.2 EC Declaration of Conformity (for EU)
See the EC declaration of conformity shipped with the device.
1.3.3 Additional Information
If you require additional information, contact Radac or its representative.
1.4 Liability
The information in this installation guide is the copyright property of Radac, The Nether-
lands.
Radac disclaims any responsibility for personal injury or damage to equipment caused by:
• Deviation from any of the prescribed procedures.
• Execution of activities that are not prescribed.
• Neglect of the safety regulations for handling tools and use of electricity.
4