1.6 Personal Safety
Warning
In hazardous areas it is compulsory to:
use personal protection and safety gear such as a hard hat, a fire-resistive overall,
safety shoes, safety glasses and working gloves.
Avoid possible generation of static electricity.
Use non-sparking tools and explosion-proof testers.
Make sure no dangerous quantities of combustible gas mixtures that are present in
the working area.
Never start working before the work permit has been signed by all parties.
Note
The emitted microwave energy is far below acceptable limits for exposure to the human
body. A maximum radiation of 0.1 [mW/cm
2
] is generated.
1.7 Warnings and Cautions
1.7.1 General
Warning
Make sure that all power to the instrument is switched off before opening the c overs of
the WaveGuide radar. Failure to do so may cause danger to persons or damage to the
equipment. Also, all the covers must be closed before s witching on the power.
1.7.2 Tools
Warning
Treat the flange surface of the cover and the housing with care. Keep the flange surface
free of dirt. The O-ring must be present and undamaged.
Warning
Use non-sparking tools and explosion-proof testers. Use suitable explosion-proof tools
(e.g. testing devices)!
6