EasyManua.ls Logo

Rauch AXIS-M 30.2 - Page 112

Rauch AXIS-M 30.2
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Faults and possible causes 9
104
Spreader application higher on
one side than the other.
Hopper empties unevenly du-
ring normal spreading.
Fertiliser bridging above the
agitator
Remove fertiliser until the
height of the protective grid
on the affected side.
Break up accumulated fer-
tiliser with a wooden stick
through the bars of the pro-
tective grid.
Outlet blocked
See blockages of the mete-
ring openings
Metering slide set incorrectly
Empty the hopper of remai-
ning fertiliser.
Check metering slide set-
ting. Refer to the chapter
on maintenance
Defective agitator
Remove fertiliser until the
height of the protective grid
on the affected side.
Open the metering slide
and break up accumulated
fertiliser with a wooden
stick through the bars of
the protective grid so that
the remaining fertiliser can
run out of the outlet.
Check the functionality of
the agitator drive. See
chapter 10.8: Checking the
agitator drive, page 119
Fault Possible cause Measure

Table of Contents

Related product manuals