EasyManua.ls Logo

Rauch MDS 8.2 - 11 Faults and Possible Causes

Rauch MDS 8.2
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Faults and possible causes
105
11
11 Faults and possible causes
Troubleshooting requirements
Switch off the PTO and the tractor engine and lock them to prevent unauthor-
ised starting.
Put down the machine on the ground.
n WARNING
Risk of injury when rectifying faults inappropriately
Delayed or incorrect repairs by unqualified personnel may result
in severe personal injury as well as in damages to the machine
and the environment.
Any faults occurring must be repaired immediately.
Only carry out repairs yourself if you have the appropriate
qualifications.
Fault Possible cause Measure
Uneven fertiliser distribution
Clumps of fertiliser on
spreading discs, spreading
vanes, outlet channels.
Remove the caked-on fer-
tiliser
Metering slides do not
open completely.
Check function of opening
slide.
Spreading vane incorrectly
adjusted.
Correct adjustment accord-
ing to fertiliser chart.

Table of Contents

Other manuals for Rauch MDS 8.2

Related product manuals