Machine settings
59
8
8 Machine settings
8.1 Safety
The following points should be noted before carrying out adjustments on
the machine:
Always set the quantity while the metering slide is closed.
In the event of metering slide actuators with return springs (version K/R),
close the ball cocks in order to prevent inadvertent escaping of fertiliser from
the hopper.
n DANGER
Danger of injury from running engine
Working on the machine while the engine is running may result in
serious injuries caused by mechanical components and escaping
fertiliser.
Wait until all rotating parts have come to a complete stop
before making any adjustments.
Switch the tractor motor off.
Remove the ignition key.
Ensure that nobody is present in the hazard zone.
n CAUTION
Risk of crushing or shearing by tensioned return springs
Versions K/R only (single-acting slide actuator):
If the return spring is tensioned when the set screw is loosened,
the stop lever may jerk and hit the end of the guide slot.
This may cause crushing injuries to fingers and/or result in injury
to the operating personnel.
Closely observe the procedure for adjusting the spreading
volume.
Never put your fingers in the guide slots of the spreading
quantity adjustment unit.
Before carrying out any adjustment work (e.g. setting of the
application rate), always close the metering slide
hydraulically.