Machine settings 8
62
8.2.2 Version Q
With the Q version, the stopper is fixed in a position outside of the scale with a
fillister head screw.
To move the stopper, loosen the fillister head screw [1] at the back.
Figure 8.2: Scale for adjusting the application rate (right in the direction of
travel,
Version Q)
[1] Fillister head screw
NOTICE
The machines of the Q versions include electronic metering slide actuators for
setting the application rate.
The electronic metering slide actuator is described in a separate operator's man-
ual for the control unit. This operator’s manual is an integral part of the operating
unit.
n CAUTION
Damage to property caused by incorrect positioning of the
metering slide
If the stop levers are positioned incorrectly, the operation of the
actuators via the QUANTRON operating unit may cause damage
to the metering slides.
Always clamp the stop levers at the maximum scale position.