Maintenance and service
125
12
Mounting the new extension vane
2. Unlock the flat springs [2]
with the adjustment lever [3].
Figure 12.17: Unlock the flat springs
3. Push the old extension vane
[4] off the main vane [5].
Figure 12.18: Extension and main vane
n DANGER
Risk of injury due to rotating machine parts
If the extension vanes are attached with the old screws and nuts,
the spreading vanes can become loose and cause severe injuries.
To assemble new components, only use the new screws,
nuts and washers supplied.
1. Push the new extension
vane [4] into the main vane
[5].
Figure 12.19: New extension vane