USER MANUAL RCS
36
32"
80 cm
M2
NET
kg/lb
NET
NET
kg/lb
NET
5x
NET
kg/lb
3 sec.
NET
kg/lb
NET
32"
80 cm
M3
8
7
9
10
11
The indicator shows the
weight.
Push the
0
button
briefly.
The first segment
starts flickering.
Use the ˄ and ˅
buttons to enter the
right values.
Place a known weight on the
forks. (M2 = 1500kg)
Confirm the entered weight by
pushing the
0
button for 3
seconds.
The display counts down and the
second calibration-point is
entered.
Push the ˄ or ˅
buttons.
The 3rd calibration
point will be shown
and both indicator
bars are flashing.
12
Place a known weight on the
forks. (M3 = 2500kg)