18
LIQUID AND GRANULAR
APPLICATIONS
6) Selecting AIM COMMAND, FAST VALVE, FST CLS VALVE, PWM VALVE or PWM CLS VALVE.
a) To select AIM COMMAND, FAST VALVE, FST CLS VALVE, PWM VALVE or PWM CLS
VALVE, step until desired code is displayed.
b) Momentarily depress , the display will now display METER CAL (liquid mode) or
SPREADER CONSTANT (granular mode).
7) For Liquid applications, enter METER CAL calibration number. For Granular applications, enter
SPREADER CONSTANT and PRODUCT DENSITY or METER CAL. Use to toggle be-
tween Spreader Constant and Product Density/Meter Cal.
8) Enter appropriate VALVE CAL calibration number (2123, 743, or 43).
9) Enter the target RATE CAL (GPA) [lit/ha] {GPK}.
10) Repeat steps 3-9 for multiple products. Active product will be highlighted.
11) Display WHEEL-SP1 or RADAR-SP2.
a) Depressing momentarily steps the display from WHEEL-SP1 to RADAR-SP2.
b) Depressing momentarily steps the display from RADAR-SP2 to WHEEL-SP1.
12) Selecting WHEEL-SP1 or RADAR-SP2.
a) To select WHEEL-SP1 or RADAR-SP2, step until desired code is displayed.
b) Momentarily depress , the display will now display SPEED CAL.
13) Enter SPEED CAL calibation number.
14) Enter BOOM CAL calibration numbers. Definition of Boom Calibration Keys.
Depressing this key displays selected boom number in display.
EXAMPLE: Boom 1 will be displayed as BOOM 1 CAL.
Depressing this key after selecting BOOM CAL changes the boom number.
EXAMPLE: BOOM 1 CAL 0 to BOOM 2 CAL 0.
Depressing this key after selecting BOOM CAL changes the boom number.
EXAMPLE: BOOM 2 CAL 0 to BOOM 1 CAL 0.
Enter Boom Data:
a) Select Boom 1 CAL.
b) Use boom width as calculated under "CALCULATING BOOM CAL".
c) If a boom is not needed, enter a "0" for the length.