32
Table 11 The waveform convenient command word detailed
Program end command, which
must be the last command of each
program.
It takes parameter 1 time to
change the power to parameter 2.
Change the power to parameter 2
at the rate of power change of
parameter 1.
The number
of times to
jump to this
line
The number of times the loop
jumps to this line
4.9 Control Modes
The laser has two control modes, namely ON mode and REM mode. The user can select the
mode to enter through the key ON the front panel.In ON mode, you can only set the power
percentage, control the light output and light off.In REM mode, you can select AD mode, enable
external control, internal modulation mode, and external modulation mode.
4.9.1 REM mode
4.9.1.1 AD mode
12, 14 pin analog voltage 0~10V
0V——0%
10——100%
The host computer sets the power percentage.
External modulation and
internal modulation OFF.
It is automatically enabled after the
main power is powered on.