19
c) Connect the power cable and control cable to the product when power supply is OFF.
d) Insert the water pipes into the inlet and outlet.
e) Check the output head and clean it if necessary. This procedure must be performed by
personnel of Raycus or authorized by Raycus. Make sure the environment is clean, or the
output cable may be contaminated.
f) Prevent the delivery cable from treading, pinching or excessive bending during
installation.
g) During the installation and disassembly process, please take care to handle the laser
output head gently, avoiding any shock.
h) In the installation of laser output cable and output head process, please make sure that the
surrounding environment is clean, other wise it may pollute the output head (do not use
fans, which actually may bring more dust).
i) The minimum bending radius of the output fiber cable of the laser should not be less than
20 cm under the non-working conditions, and the minimum bending radius should not be
less than 30 cm when the laser is working.
CAUTION:
All the cables can only be connected when power supply is OFF. Hot
plug may damage the laser.
CAUTION:
The laser output optical cable should be kept as natural as possible and
not be distorted.
The too small bending radius of the output fiber cable will damage the
laser.
CAUTION:
Make sure the aperture and the cavity of the processing head is clean.
Keep the protective cap properly, prevent it from contamination; Or
the aperture will be contaminated when capped.