EasyManua.ls Logo

Raymarine G-Series system - 4.4 Monitor connections

Raymarine G-Series system
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G-Series Installation & Commissioning 38
4.4 Monitor connections
Connect the G-Series marine displays to both the GPM400 proces-
sor and SeaTalk
hs
switch.
Monitors may be connected to the GPM400 using either VGA or
DVI cable.
Repeat displays
Repeat displays (if used) show the same information / page as the
master display. For this reason each display within a Nav Station
must be connected to a different GPM400.
Note: During start-up only the master display will show the boot
sequence and start-up information.
Maximum quantity of monitors
The G-Series system will support up to 8 monitors (2 per GPM400).
CameraCamera
Monitor
GPM 400
Repeat Monitor (optional)
DVI or VGA
DVI or VGA
SeaTalk
hs
SeaTalk
hs
SeaTalk
hs
D10074-1
SeaTalk
hs
switch
Composite video
Composite video
D10075-1
Power Cable
DVI
Input
SeaTalk
hs
SeaTalk
hs
VGA
Input
VGA
input
adaptor
cable
DVI
Input
VGA
Input
Network selector switch
(in UP position)
Monitor
HS switch
GPM 400
OR

Table of Contents

Related product manuals