EasyManua.ls Logo

Raymarine i40 - User Calibration - i40 Depth

Raymarine i40
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.3Usercalibrationi40Depth
Calibrationproceduresaredependantoninstrument
displayvariant.
Usercalibrationoptionsinclude:
DepthdisplayresponseDictatestherateat
whichtheinstrumentdisplayrespondstochanges
indepthdata.
*UnitsfordepthreadingsAssignstheunitof
measureusedfordepthrelatedreadings.
*DepthoffsetAssignsanoffsettothedepth
reading.
*ShallowalarmlockLockstheShallowalarm.
Note:*Thesesettingsareonlyavailableonunits
whentheinstrumentstatussettoMaster(see
IntermediateCalibrationfordetailsofchangingthe
displaytobeMasterorRepeater).
DepthOffset
Depthsaremeasuredfromthetransducertothesea
bed,butyoucanapplyanoffsetvaluetothedepth
data,sothatthedisplayeddepthreadingrepresents
thedepthtotheseabedfromeitherthekeelorthe
waterline.
Beforeattemptingtosetawaterlineorkeel
offset,ndouttheverticalseparationbetweenthe
transducerandeitherthewaterlineorthebottomof
thekeelonyourvessel,asappropriate.Thensetthe
appropriatedepthoffsetvalue.
D9343--2
1 2 3
1
Waterlineoffset
2
Transducer/Zerooffset
3
Keeloffset
Ifanoffsetisnotapplied,displayeddepthreadings
representthedistancefromthetransducertothe
seabed.
Calibratingdepth
Tocalibrateyouri40Depthfollowthestepsbelow.
Duringnormaloperation:
1.SimultaneouslypressandholdtheDownand
Actionbuttonsfor2secondstodisplaytheUser
Calibrationpage.
10
15
20
25
30
35
40
45
50
55
60
5
2
+
D12 4 14 -1
2.PresstheActionbuttontodisplaytheDepth
Responsepage.
CAL
D12 4 01 -1
3.UsetheUpandDownbuttonstoadjustthe
DepthResponsetotherequiredlevel.
Thedefaultlevelis12.Thelevelsavailableare1
to15withlevel1beingtheslowestupdaterate
andlevel15thequickest.
4.PresstheActionbuttontodisplaytheDepth
unitspage.
CAL
D12 4 02 -1
5.UsetheUpandDownbuttonstoselectthe
requiredunitofmeasurementfordepthreadings.
Theunitsofmeasureavailablefordepthreadings
are:
FTfeet(default)
MMeters
FAFathoms
6.PresstheActionbuttontodisplaytheDepth
Offsetpage.
CAL
D12 4 00 -1
7.UsetheUpandDownbuttonstoselectthe
requireddepthoffsetvalue.
Thedepthoffsetcanbesettothefollowing
values:
Keelvaluesbetween–9.9to–0.1
OFST(zerooffset)(default)0.0
W/L(Waterline)valuesbetween0.1to9.9
8.PresstheActionbuttontodisplaytheShallow
AlarmLockpage.
CAL
D12 4 07 -1
9.UsetheUpandDownbuttonstoswitchthe
shallowalarmlockonandoff.
WiththeShallowAlarmLockOnyoucannot
changethealarmthresholdorswitchthealarm
onandoff.Tochangethealarmthresholdor
switchthealarmonandoffthealarmlockmust
besettoOff(default).
10.T osaveyoursettingsandreturntonormal
operationfromanypage,simultaneouslypress
andholdtheDownandActionbuttonsfor2
seconds.
i40Depth
47

Table of Contents

Other manuals for Raymarine i40

Related product manuals